[{"data":1,"prerenderedAt":61},["ShallowReactive",2],{"q-105170-arch_construction-50":3},{"question":4,"neighbors":26,"sameNumber":45,"prev":34,"next":37},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":20,"answerS":11,"answerNote":11,"images":21,"explanation":22,"withheld":11,"deepChars":23,"freq":24,"indexable":25},"arch-105170-801-0103-050","architect","105170",105,"建築構造與施工",50,null,"當建築物之柱牆與梁或樓版同時澆置混凝土時，須先澆置柱牆至少若干小時後，方可繼續澆置其上之梁版？",{"A":14,"B":15,"C":16,"D":17},"1","2","3","4",[19],"B","single",[],"本題考點：梁或版與其支承之柱或牆「同次澆置」混凝土時，柱牆與梁版之間必須保留的最短間隔時間，以及這段等待時間要防止的裂縫機制。\n【正解理由】《結構混凝土施工規範》第 9.3.6 節規定，若梁或版與其支承之柱或牆同次澆置混凝土時，須俟柱或牆之混凝土達無塑性且至少2小時後，方可澆置梁或版之混凝土。這個規定有兩個要件，必須同時滿足：一是狀態要件，柱或牆的混凝土已達「無塑性」；二是時間要件，至少2小時。題目問的是「至少若干小時」，對應的正是時間要件的下限 2 小時，故選 B。\n【逐項排除】\n(A) 不符題目所問。1 小時低於《結構混凝土施工規範》第 9.3.6 節所定的最短等待時間。柱牆混凝土在澆置初期仍處於塑性狀態，會因泌水、漏漿與體積收縮而持續下沉、變短；若此時就接著澆置梁版，梁版底部與柱牆頂部之間會因柱牆後續下沉而拉開，形成水平裂縫。改成「至少 2 小時且柱牆混凝土達無塑性」才符合《結構混凝土施工規範》第 9.3.6 節。\n(B) 符合題目所問，本題答案。2 小時就是《結構混凝土施工規範》第 9.3.6 節條文寫明的下限，解說也說明梁版之混凝土澆置應延後至少2小時，俟先期澆置之混凝土穩定後方可澆置。\n(C) 不符題目所問。等待 3 小時固然不違反「至少 2 小時」的下限，但題目問的是「至少若干小時」，也就是規範所定的最低門檻，3 小時不是這個門檻。此外，等待時間並非越長越好：時間拖得過久，柱牆頂部混凝土已逐漸硬化，梁版再澆置時兩次混凝土之間不易結合，反而有形成冷縫的疑慮，所以規範的寫法是「下限加上無塑性狀態」，而不是單純拉長時間。\n(D) 不符題目所問。理由與 (C) 相同：4 小時雖然大於下限，但不是規範所定的最短等待時間，與題目所問的「至少」不符；過長的間隔同樣會提高梁柱交接處形成冷縫的機會。\n【記憶點】柱牆與梁版同次澆置：柱牆先澆、等它「無塑性且至少2小時」，再澆梁版，防的是柱牆沉縮拉出的水平裂縫。",872,1,true,[27,30,33,36,39,42],{"number":28,"session":7,"stem":29},47,"有關石材覆面的外牆乾式工法的敍述，下列何者錯誤？",{"number":31,"session":7,"stem":32},48,"有關地上結構體安全應注意事項，下列何者與地下室逆打工法無直接關係？",{"number":34,"session":7,"stem":35},49,"模板施工時，脫模劑之適當使用時機為何？",{"number":37,"session":7,"stem":38},51,"「混凝土坍度」係指下列何者？",{"number":40,"session":7,"stem":41},52,"下列四圖所示，何者為混凝土澆置施工造成的冷縫缺陷？",{"number":43,"session":7,"stem":44},53,"國內建築物外牆面材較少留設龜裂誘發縫，形成不規則裂縫修補困難，一般留設龜裂誘發縫之原…",[46,49,52,55,58],{"number":10,"session":47,"stem":48},"114180","如下圖所示，網釘工法是一種針對老舊建物外牆瓷磚改修的技術，其特性在於可最大限度地減少…",{"number":10,"session":50,"stem":51},"113190","下圖為一種浴廁「同層排水（Same Floor Draining System）」作…",{"number":10,"session":53,"stem":54},"112190","有關版基礎開挖後之回填，下列敘述何者正確？",{"number":10,"session":56,"stem":57},"111180","RC 柱的模板常在最下端留小活門，其功能為下列何者？",{"number":10,"session":59,"stem":60},"110180","鋼構件有防火需求時，常用的防火工法或材料不包含下列那種？",1791863214719]