[{"data":1,"prerenderedAt":62},["ShallowReactive",2],{"q-106180-arch_construction-46":3},{"question":4,"neighbors":27,"sameNumber":46,"prev":35,"next":38},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":20,"answerS":11,"answerNote":11,"images":21,"explanation":23,"withheld":11,"deepChars":24,"freq":25,"indexable":26},"arch-106180-801-0103-046","architect","106180",106,"建築構造與施工",46,null,"鋼骨以螺栓接合時，其螺栓群之鎖緊順序何者正確？",{"A":14,"B":15,"C":16,"D":17},"3-2-1","1-2-3","3-1-2","1-3-2",[19],"B","single",[22],"\u002Fimages\u002Farch-106180-801-0103-046.png","本題考點：鋼構造螺栓群（拼接板接合）的鎖緊順序，原理是「由接合群中央往外側逐列鎖緊」，讓板層之間的間隙與翹曲被一路推向自由邊排出。\n【正解理由】依題圖，這是一個鋼板對接、上下各加一片拼接板的接合，中央標有 C.L.（接合中心線），兩側各有三列螺栓，由中心線往外依序編為 1、2、3。螺栓接合要靠螺栓的鎖緊力把母材與拼接板壓成密貼的一體，摩阻型接合更是靠板面之間的接觸壓力產生摩擦來傳力。板材在加工、搬運後難免有微小的翹曲或不平，若先鎖外側，外側先被夾死，中間殘留的隆起與間隙就被「關」在接合內部，之後再鎖內側也壓不平，內側螺栓的夾緊力與板面接觸就不足。反過來從最靠近中心線的 1 號列開始，接著鎖 2 號、最後鎖 3 號，每鎖一列就把板層的空隙往外擠一段，最後由板端排出，整個接合面才能均勻密貼。所以鎖緊順序是由中央向外側的 1-2-3，故選 B。\n【逐項排除】\n(A) 3-2-1 是由最外側往中心線鎖，方向正好相反：外側先夾緊後，中間的翹曲與間隙沒有出路，被困在靠近中心線的位置，使內側螺栓的板面接觸不足。改成由中心線往外的 1-2-3 才對。\n(B) 1-2-3 由最靠近中心線的列開始，逐列往外推進到最外側，間隙一路被趕向板端排出，接合面能均勻密貼，符合螺栓群由中央向外鎖緊的原則，正確。\n(C) 3-1-2 先鎖最外側的 3 號列，一開始就把外緣夾死，之後無論再鎖哪一列，間隙都排不出去；而且順序跳動、不是連續往同一方向推進。改成 1-2-3 才對。\n(D) 1-3-2 雖然從中心線的 1 號列起鎖，但接著跳到最外側的 3 號列，等於把 2 號列所在的那一段兩頭都先夾住，間隙被封在 1 與 3 之間，最後鎖 2 號也壓不平。起點對了，但中間跳列，改成依序 1-2-3 才對。\n【記憶點】螺栓群鎖緊口訣「由中往外、逐列推進」，像擀麵皮把氣泡往外趕，先鎖外側或中途跳列都會把間隙關在裡面。",714,1,true,[28,31,34,37,40,43],{"number":29,"session":7,"stem":30},43,"鋼骨建築梁柱結構銲接施工時，應從何處開始銲接？",{"number":32,"session":7,"stem":33},44,"鋼骨建築結構銲接施工時，銲條須預熱烘乾之目的為何？",{"number":35,"session":7,"stem":36},45,"就現行法令而言，下列何種防火被覆工法無法滿足 3.6 m 樓高鋼構造建築，及其鋼梁 …",{"number":38,"session":7,"stem":39},47,"普通混凝土施工時，有關澆置完成表面之處理，下列敘述何者正確？",{"number":41,"session":7,"stem":42},48,"依據混凝土施工規範之規定，工地新澆置之一般混凝土養護至少須持續若干日？",{"number":44,"session":7,"stem":45},49,"下列何種玻璃因成品製成後不能再予切割，所以須訂製？①浮式及磨光平板玻璃 ②強化玻璃 …",[47,50,53,56,59],{"number":10,"session":48,"stem":49},"114180","基礎工法中，有關預力混凝土樁（P.C 樁）與一般離心式鋼筋混凝土樁（R.C 樁）之比…",{"number":10,"session":51,"stem":52},"113190","鋼構造之高強度螺栓施工安裝，下列何項描述錯誤？",{"number":10,"session":54,"stem":55},"112190","依營造安全衛生設施標準規定，對於施工構臺應辦理項目，下列敘述何者錯誤？",{"number":10,"session":57,"stem":58},"111180","依據 CNS12642 公共兒童遊戲場設備適用範圍之規定，其使用者年齡範圍為：",{"number":10,"session":60,"stem":61},"110180","下列何者不是「高性能節能玻璃綠建材」規範範圍？",1791863212684]