[{"data":1,"prerenderedAt":61},["ShallowReactive",2],{"q-106180-arch_construction-53":3},{"question":4,"neighbors":26,"sameNumber":45,"prev":34,"next":37},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":20,"answerS":11,"answerNote":11,"images":21,"explanation":22,"withheld":11,"deepChars":23,"freq":24,"indexable":25},"arch-106180-801-0103-053","architect","106180",106,"建築構造與施工",53,null,"受風雨侵蝕之 RC 構造物，有關鋼筋保護層之敘述下列何者正確？",{"A":14,"B":15,"C":16,"D":17},"柱保護層至少應達 40 mm","梁保護層至少應達 30 mm","牆保護層至少應達 20 mm","版保護層至少應達 10 mm",[19],"A","single",[],"本題考點：鋼筋混凝土構材在「受風雨侵蝕」環境下的最小鋼筋保護層厚度，以及保護層的量測方式與「受風雨侵襲」的判定標準。\n【正解理由】《結構混凝土施工規範》第 5.6.1 節說明混凝土保護層的功能是保護鋼筋抵抗天候及其他侵蝕；保護層自混凝土表面量至鋼筋最外表面，有肋筋、箍筋或螺箍筋圍封主筋時，量至橫向鋼筋的最外緣；所謂受風雨侵襲，是指直接暴露於濕度變化及溫度變化之處。保護層的具體厚度由設計者依設計規範決定並明確標示於工程圖說，《結構混凝土施工規範》第 5.1.3 節也指明鋼筋保護層厚度等細節應按「結構混凝土設計規範」辦理。在該設計規範的體系裡，現場澆置的構材一旦受風雨侵蝕，不分柱、梁、牆、版，最小保護層都要比室內不受風雨的構材加厚：較細的鋼筋至少 40 mm，較粗的鋼筋還要更厚。題目四個選項中，只有「柱保護層至少應達 40 mm」與外露構材的下限一致。故選 A。\n【逐項排除】\n(A) 正確。柱是直接面對風雨的立面構材，表面承受濕度與溫度的反覆變化，保護層下限為 40 mm；題目寫「至少應達 40 mm」，說的正是這個下限，主筋較粗時要求還會再提高，並不影響這句敘述成立。\n(B) 錯誤。梁受風雨侵蝕時，與柱一樣適用外露構材的加厚要求，下限同樣是 40 mm，不是 30 mm；30 mm 低於外露構材的下限，二氧化碳與含氯水分較快滲到鋼筋位置，鋼筋提早鏽蝕。另須分辨《結構混凝土施工規範》第 5.6.1 節的但書：梁、版底面通常不被認為直接暴露，除非承受乾濕交替作用（如結露、漏水、流水）；但本題已設定構造物「受風雨侵蝕」，就應採外露構材的保護層，改成「至少應達 40 mm」才對。\n(C) 錯誤。牆在室內時保護層可以較薄，20 mm 這個量級是室內不受風雨之牆、版的下限；同一道牆一旦成為外牆、直接受風雨侵蝕，就要比照外露構材至少 40 mm。《建築技術規則建築構造編》第 170 條之 8 除要求結構牆鋼筋保護層厚度依循設計規範外，還另外要求外牆面採取適當之防水處理，可見外牆面的耐久性要求比室內牆更高，不能沿用室內牆的厚度。\n(D) 錯誤。版受風雨侵蝕時（例如屋頂版頂面、外露的陽臺版或雨遮），同樣至少 40 mm；10 mm 連室內版的保護層都達不到，鋼筋幾乎貼著表面，混凝土也難以在鋼筋外側確實填實，極易發生鏽脹、保護層剝落。改成「至少應達 40 mm」才對。\n【記憶點】受風雨侵蝕的現場澆置構材，柱、梁、牆、版一律加厚、至少 40 mm 起跳；只有室內不受風雨時，牆、版才可比梁、柱薄。",810,1,true,[27,30,33,36,39,42],{"number":28,"session":7,"stem":29},50,"有關電梯昇降設備，下列敘述何者錯誤？",{"number":31,"session":7,"stem":32},51,"有關石膏板之設計與施工，下列敘述何者錯誤？",{"number":34,"session":7,"stem":35},52,"有關混凝土坍度何者敘述正確？",{"number":37,"session":7,"stem":38},54,"關於混凝土施工縫之處理，下列何者錯誤？",{"number":40,"session":7,"stem":41},55,"關於鋼骨建築構造的性質及施工，下列何者錯誤？",{"number":43,"session":7,"stem":44},56,"下列鋼筋混凝土柱筋搭接位置示意圖何者正確？搭接處搭接處柱主筋",[46,49,52,55,58],{"number":10,"session":47,"stem":48},"114180","下圖為某案場輕隔間牆轉角詳圖，下列有關使用材料的敘述何者最不恰當？ ① ② ③ ④",{"number":10,"session":50,"stem":51},"113190","下圖為某案場屋頂平台地坪詳圖，下列敘述何者錯誤？",{"number":10,"session":53,"stem":54},"112190","依結構耐震施工品質管制規定，施工品質管制計畫報告書中不包括下列何者？",{"number":10,"session":56,"stem":57},"111180","下圖為型框噴植式邊坡穩定法之正視圖與剖面示意圖，下列敘述何者錯誤？",{"number":10,"session":59,"stem":60},"110180","框組壁式工法（亦稱為 2 × 4 工法）為常見於北美的一種木構造工法，其特徵為各木構…",1791863212738]