[{"data":1,"prerenderedAt":61},["ShallowReactive",2],{"q-106180-arch_construction-75":3},{"question":4,"neighbors":26,"sameNumber":45,"prev":34,"next":37},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":20,"answerS":11,"answerNote":11,"images":21,"explanation":22,"withheld":11,"deepChars":23,"freq":24,"indexable":25},"arch-106180-801-0103-075","architect","106180",106,"建築構造與施工",75,null,"大面積單元式帷幕牆之風雨試驗，其試體之寬度不得少於幾個標準單元（構件）？",{"A":14,"B":15,"C":16,"D":17},"1","2","3","6",[19],"C","single",[],"本題考點：帷幕牆性能試驗（風雨試驗，包括水密、氣密與耐風壓試驗）的試體規模，特別是大面積單元式帷幕牆試體寬度的最低要求。\n【正解理由】單元式帷幕牆是在工廠把框架、玻璃或面板組裝成一片片單元，再到現場逐片吊掛、彼此以公母料互相插接。它最容易出問題的地方不是單元內部，而是單元與單元之間的接縫：雨水滲入、空氣洩漏、受風壓時接縫錯動，多半發生在這裡。試體寬度取 3 個標準單元，中間那一片的左右都與相鄰單元以真實接縫相接，邊界條件與實際立面上的單元相同；兩側單元則負責與試驗框架銜接。這樣才能在試驗中重現現場最關鍵的單元間接縫，並讓中間單元的受力與變形具代表性，因此試體寬度不得少於 3 個標準單元。故選 C。\n【逐項排除】\n(A) 不符合。只有 1 個單元時，試體沒有任何單元與單元之間的接縫，四周都直接接在試驗框架上，只能檢驗單元本身，無法檢驗單元式帷幕牆最關鍵的插接部位，代表性不足。\n(B) 不符合。2 個單元雖然有一道單元間接縫，但每一片單元都有一側直接接在試驗框架上，沒有任何一片的邊界條件與實際立面相同，接縫兩側的變形也受框架束制，仍不足以代表現場狀態。\n(C) 符合。3 個單元是讓中間單元左右兩側都為真實單元接縫的最小寬度，可同時檢驗單元本身與單元間接縫的水密、氣密與受風壓性能。\n(D) 不符合。6 個單元固然也能涵蓋單元間接縫，但題目問的是「不得少於」的最低數量，6 超過了下限，不是答案；試體越大，試驗設備與費用也越高，下限的意義正是在代表性足夠的前提下控制試體規模。\n【記憶點】單元式帷幕牆試體至少 3 個單元寬：中間那片左右都是真接縫。",503,1,true,[27,30,33,36,39,42],{"number":28,"session":7,"stem":29},72,"機關辦理統包工程時，如人力與能力不足，施工期間的監造工作應由下列何者執行？",{"number":31,"session":7,"stem":32},73,"鋼構造建築物施工圖，英文字母（GT）為何？",{"number":34,"session":7,"stem":35},74,"依公有建築物施工階段契約約定權責分工表之內容，工程竣工圖說作業下列何者錯誤？①工程竣…",{"number":37,"session":7,"stem":38},76,"含高碳之鋼筋較適合之續接方式為何？①搭接 ②瓦斯壓接 ③銲接 ④續接器",{"number":40,"session":7,"stem":41},77,"下列建築管理作業，何者需由設計人會同申請，或於申請書中簽章？①建造執照申請 ②申請開…",{"number":43,"session":7,"stem":44},78,"下列事項的辦理順序，何者正確？①申辦電信設計許可 ②申辦都市設計審議許可 ③申辦地目…",[46,49,52,55,58],{"number":10,"session":47,"stem":48},"114180","分工結構圖係指依作業性質之不同，將工程細分至一易於掌握、管理的單位，以作為時程管理、…",{"number":10,"session":50,"stem":51},"113190","下列那一種圖可將工程細分至易於掌握與管理，以作為進度安排、成本會計管理？",{"number":10,"session":53,"stem":54},"112190","關於木構造估價要點，下列敘述何者錯誤？",{"number":10,"session":56,"stem":57},"111180","規模相同時，SRC、SS、RC 構造施工之特性比較，下列何者錯誤？",{"number":10,"session":59,"stem":60},"110180","有關地基調查報告，採地下探勘方法，下列敘述何者錯誤？",1791863212901]