[{"data":1,"prerenderedAt":61},["ShallowReactive",2],{"q-108180-arch_construction-41":3},{"question":4,"neighbors":26,"sameNumber":45,"prev":34,"next":37},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":20,"answerS":11,"answerNote":11,"images":21,"explanation":22,"withheld":11,"deepChars":23,"freq":24,"indexable":25},"arch-108180-801-0103-041","architect","108180",108,"建築構造與施工",41,null,"有關各種塗裝缺陷之現象與原因，下列敘述何者錯誤？",{"A":14,"B":15,"C":16,"D":17},"白化：呈現塗膜發白混濁，原因之一為空氣濕度過高，空氣中之水分凝集於塗面而發白混濁","剝離：呈現塗膜由木面剝離，原因之一為木材的樹脂油分太多","失光：呈現塗膜不光滑，原因之一為稀釋劑的選用不當","砂皮：塗面有粗粒、不平滑，原因之一為木面有油漬或水分",[19],"D","single",[],"本題考點：木作塗裝常見缺陷（白化、剝離、失光、砂皮）的現象與成因對應。\n【正解理由】判讀塗裝缺陷要把「現象」與「成因」配對：白化與空氣溼氣有關，剝離與底材表面的附著條件有關，失光與溶劑及塗膜流展、乾燥有關，砂皮則與塗料或環境中的顆粒雜質有關。選項 D 把「砂皮」的成因寫成「木面有油漬或水分」，但砂皮的現象是塗面出現細小顆粒、觸摸粗糙，成因在於塗料中混入灰塵、結皮碎片或分散不完全的顏料粒，或施工環境的塵埃落在未乾塗面，以及噴塗時霧粒在空中半乾才落到塗面；木面有油漬或水分，造成的是塗料被油污排開而形成凹陷的「縮孔」、塗膜附著不良的「剝離」或水氣受熱膨脹的「起泡」，不是砂皮。因此選項 D 的敘述錯誤，故選 D。\n【逐項排除】\n(A) 白化：敘述正確。溶劑快速揮發時會帶走汽化熱，使塗面溫度下降到露點以下，空氣中的水氣凝結在尚未乾燥的塗膜上，與樹脂產生分離而呈乳白混濁；空氣溼度愈高愈容易發生，因此「空氣濕度過高、水分凝集於塗面」是白化的典型原因，現象與成因配對正確。\n(B) 剝離：敘述正確。松類等樹脂（松脂）油分多的木材，表面油分會阻隔塗料滲入木纖維，塗膜與木面之間的附著力不足，乾燥收縮或溫溼度變化後便成片剝落；這正是剝離的典型成因之一。木材含水率過高、表面髒污未清除，也屬於同一類「底材附著不良」的原因。\n(C) 失光：敘述正確。稀釋劑選用不當，例如溶解力不足使樹脂析出，或揮發速度不合使塗膜來不及流平，塗膜表面在微觀上變得粗糙，光線被散射而失去光澤；此外底層未乾即塗上層、底材過度吸收塗料、高溼環境下塗裝，也會造成失光。題目以「稀釋劑的選用不當」作為原因之一，配對正確。\n(D) 砂皮：敘述錯誤。砂皮的現象描述（塗面有粗粒、不平滑）沒有錯，錯在成因：砂皮的原因之一應為「塗料或施工環境中混入灰塵、雜質等顆粒」（或塗料未經過濾、結皮碎片混入）；「木面有油漬或水分」對應的缺陷是縮孔、剝離或起泡，屬於底材處理不良，不是砂皮的成因。\n【記憶點】溼氣致白化、樹脂油分致剝離、稀釋劑不當致失光、灰塵顆粒致砂皮；油漬水分對應的是縮孔與剝離。",620,1,true,[27,30,33,36,39,42],{"number":28,"session":7,"stem":29},38,"免震構造內，積層橡膠之特徵與用途，下列何者錯誤？",{"number":31,"session":7,"stem":32},39,"有關鋼構造耐震補強策略之敘述，下列何者錯誤？",{"number":34,"session":7,"stem":35},40,"在臺灣外牆面磚張貼工程中，常用「海菜粉」添加於無機接著劑（水泥砂漿）作為黏著材料，以…",{"number":37,"session":7,"stem":38},42,"混凝土澆置施工時，常需在現場進行取樣及試驗，其不包括下列何者？",{"number":40,"session":7,"stem":41},43,"建築物屋頂及外牆皆留有伸縮縫時，該如何處置？",{"number":43,"session":7,"stem":44},44,"建築物地下室防水工程之施作概念，何者最佳？",[46,49,52,55,58],{"number":10,"session":47,"stem":48},"114180","有關玻璃外牆（glass facade）之圖示之相關敘述，何者錯誤？結構膠支承構件層…",{"number":10,"session":50,"stem":51},"113190","一般鋼構造房屋工地現場的施工順序，何者正確？①樑構件吊裝 ②銲接鎖固 ③基礎螺栓埋設…",{"number":10,"session":53,"stem":54},"112190","有關室內裝修工程的敘述，下列何者錯誤？",{"number":10,"session":56,"stem":57},"111180","有關隔震工法之敘述，下列何者錯誤？",{"number":10,"session":59,"stem":60},"110180","下列何者不是 CNS3299-12「陶瓷面磚試驗法-第 12 部：防滑性試驗法」進行…",1791863209805]