[{"data":1,"prerenderedAt":61},["ShallowReactive",2],{"q-111180-arch_construction-5":3},{"question":4,"neighbors":26,"sameNumber":45,"prev":34,"next":37},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":20,"answerS":11,"answerNote":11,"images":21,"explanation":22,"withheld":11,"deepChars":23,"freq":24,"indexable":25},"arch-111180-801-0103-005","architect","111180",111,"建築構造與施工",5,null,"有關防水之敘述，下列何者正確？",{"A":14,"B":15,"C":16,"D":17},"屋簷的滴水槽設計是利用毛細管現象之防水原理","設置減壓空間（等壓空間）是利用材料的氣密性來達成防水效果","止水帶防水工法適合用於先後澆置混凝土的續接處","雨天或下雪時屋頂防水還是可以施作",[19],"C","single",[],"本題考點：外牆與屋頂防水的基本原理（重力、毛細現象、氣壓差）與止水帶工法的適用位置，以及防水施工對天候的要求。\n【正解理由】止水帶是埋在混凝土接縫裡的帶狀止水構材。《結構混凝土施工規範》第 6.5.3 節說明止水帶的裝設係應用分離模板，澆置混凝土時須特別小心，不可使澆置混凝土內的止水帶彎曲變形或移位，且止水帶周圍的混凝土須充分搗實，以免蜂窩導致日後止水失效。所謂分離模板，就是把一次澆置的範圍在接縫處隔開：先澆的一側先把止水帶的一半埋入，拆模後再澆另一側，把另一半埋入，止水帶便橫跨新舊混凝土的交界。《結構混凝土施工規範》第 6.5.2 節並說明止水帶以橡膠、塑膠或金屬等材料製成。先後澆置混凝土所形成的續接處（施工縫）正是水最容易沿介面滲入的位置，止水帶工法就是為這種接縫設計的，所以 (C) 的敘述正確，故選 C。\n【逐項排除】\n(A) 錯誤。屋簷的滴水槽是在簷口底面做出一道凹槽，雨水沿著簷底面往內流到凹槽邊緣時，附著的水膜被凹槽切斷，只能靠重力在此處滴落，無法繼續往牆面方向爬行。它的原理是「切斷」水沿表面爬行（表面張力與毛細作用）的路徑，再以重力讓水滴下，而不是「利用」毛細管現象。改成「滴水槽是阻斷毛細與表面張力的爬水路徑、利用重力使水滴落」才對。\n(B) 錯誤。減壓空間（等壓空間）是在外牆接縫內設置一個與外氣相通的空腔，讓空腔內的氣壓與外側風壓趨於相等，接縫內外沒有氣壓差，雨水就失去被「吸」或「壓」進室內的驅動力。它的防水原理是「氣壓平衡（等壓原理）」，關鍵在消除壓力差；氣密性要求在空腔的室內側那一道，作用是讓空腔能維持等壓，並不是靠材料的氣密性直接把水擋住。改成「設置減壓空間是利用等壓原理消除內外氣壓差來達成防水」才對。\n(C) 正確。止水帶以分離模板裝設、在先後兩次澆置中分別埋入，適用於先後澆置混凝土的續接處，用來截斷水沿新舊混凝土介面滲入的路徑。\n(D) 錯誤。屋頂防水層（瀝青、防水塗膜、防水毯等）要能與底層緊密黏著並完整成膜，底層必須乾燥、清潔；雨天或下雪時底層含水，塗料與膠黏劑無法附著、塗膜會被稀釋或起泡，日後會出現剝離與滲漏，因此遇雨雪應停止施作。同樣屬怕水的室外濕式作業，《結構混凝土施工規範》第 9.5.1 節對室外混凝土澆置也要求避免在下大雨、下雪及刮大風等惡劣天候下進行，不得已時要採取經監造者認可的保護措施，可以對照理解。改成「雨天或下雪時不宜施作屋頂防水」才對。\n【記憶點】滴水槽靠重力斷水、等壓空間靠消除壓差、止水帶埋在先後澆置的接縫、防水施工要乾燥天候。",687,1,true,[27,30,33,36,39,42],{"number":28,"session":7,"stem":29},2,"關於具有 1 小時以上防火時效之牆壁，下列敘述何者錯誤？",{"number":31,"session":7,"stem":32},3,"有關建築外牆採光規定，下列敘述何者錯誤？",{"number":34,"session":7,"stem":35},4,"建築構造中所謂的止水帶應用於：",{"number":37,"session":7,"stem":38},6,"屋頂上往往設有眾多的建築設備和管線，下列四張照片中，何者較能維持屋頂防水層的完整性？…",{"number":40,"session":7,"stem":41},7,"有關常時關閉式之防火門之規定，下列敘述何者錯誤？",{"number":43,"session":7,"stem":44},8,"一般建材有瓷製品、石製品及陶製品，若以吸水率及燒成溫度來區分，下列何者正確？",[46,49,52,55,58],{"number":10,"session":47,"stem":48},"114180","有關我國綠建材標章之「高性能節能綠建材」的材料評定基準之敘述，下列何者錯誤？",{"number":10,"session":50,"stem":51},"113190","以物理處理法強化而成的安全玻璃，受外力而破裂時，顆粒形成鈍角，比較不傷害人體。此種處…",{"number":10,"session":53,"stem":54},"112190","SRC 矩形柱，若主筋間距過大時須加配軸向輔助筋，下列敘述何者錯誤？",{"number":10,"session":56,"stem":57},"110180","某建築師欲以六種吸水率不同的陶瓷面磚，選用於某河濱公園設計案的戶外地坪。若以 CNS…",{"number":10,"session":59,"stem":60},"109180","下圖有關 RC 柱（高度 3 公尺）的軸壓力破壞過程，下列敘述何者錯誤？",1791863202244]