[{"data":1,"prerenderedAt":61},["ShallowReactive",2],{"q-112190-arch_environment-15":3},{"question":4,"neighbors":26,"sameNumber":45,"prev":34,"next":37},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":20,"answerS":11,"answerNote":11,"images":21,"explanation":22,"withheld":11,"deepChars":23,"freq":24,"indexable":25},"arch-112190-801-0104-015","architect","112190",112,"建築環境控制",15,null,"下列關於相對濕度的敘述何者錯誤？",{"A":14,"B":15,"C":16,"D":17},"空氣溫度上升時，相對濕度降低","空氣溫度上升時，飽和水蒸氣壓不會改變","相對濕度即空氣中實際水蒸氣壓與飽和水蒸氣壓的比值","阿斯曼（Assmann）通風溫濕度計只能量到乾球溫度與濕球溫度，無法直接量測相對濕度",[19],"B","single",[],"本題考點：濕空氣的基本性質，也就是相對濕度的定義、飽和水蒸氣壓與溫度的關係，以及阿斯曼通風乾濕球溫濕度計的量測原理。題目問的是「錯誤」的敘述。\n【正解理由】飽和水蒸氣壓是空氣在某一溫度下所能容納水蒸氣的上限壓力，它只由溫度決定，而且隨溫度升高而明顯增大：溫度越高，水分子動能越大，空氣在達到飽和之前能容納的水蒸氣就越多。因此「空氣溫度上升時，飽和水蒸氣壓不會改變」與物理事實相反，正確的說法是「空氣溫度上升時，飽和水蒸氣壓隨之增大」。這個關係正是相對濕度會隨溫度變動的根源：分子（實際水蒸氣壓）不變而分母（飽和水蒸氣壓）變大，比值自然變小。B 的敘述錯誤，故選 B。\n【逐項排除】\n(A) 敘述正確。在空氣中水蒸氣含量不變（實際水蒸氣壓、絕對濕度不變）的一般情境下，溫度上升使飽和水蒸氣壓變大，相對濕度＝實際水蒸氣壓／飽和水蒸氣壓的分母變大，比值就下降。反過來，溫度下降時相對濕度上升，降到露點溫度時相對濕度達到飽和而開始結露。要注意這個敘述成立的前提是水蒸氣量沒有同時增加；若加熱同時加濕，相對濕度就不一定降低。\n(B) 敘述錯誤，為本題答案。錯在把飽和水蒸氣壓當成與溫度無關的定值。飽和水蒸氣壓是溫度的函數，溫度上升時增大、溫度下降時減小；空氣線圖上的飽和曲線往高溫側一路上揚，就是這個關係的圖形。改成「空氣溫度上升時，飽和水蒸氣壓增大」才正確。\n(C) 敘述正確。相對濕度的定義就是空氣中實際的水蒸氣壓與同溫度下飽和水蒸氣壓的比值，通常以百分比表示。它描述的是「離飽和還有多遠」，而不是空氣裡到底有多少水；描述水蒸氣絕對含量的是絕對濕度（每單位質量乾空氣所含水蒸氣的質量）或水蒸氣分壓。\n(D) 敘述正確。阿斯曼通風乾濕球溫濕度計由兩支溫度計組成，一支量乾球溫度，另一支感溫部包覆濕紗布量濕球溫度，並以發條或馬達驅動風扇強制通風，使濕球周圍風速穩定，同時以鍍亮的遮蔽管阻擋輻射熱。儀器本身直接讀到的只有乾球溫度與濕球溫度，相對濕度要再由兩者的差值查濕度表或空氣線圖求得，所以說它無法直接量測相對濕度。\n【記憶點】飽和水蒸氣壓只看溫度、隨溫度升高而變大；水蒸氣量不變時，溫度升高相對濕度就下降。",850,1,true,[27,30,33,36,39,42],{"number":28,"session":7,"stem":29},12,"室內空間有眩光問題產生時，下列那些手法較可能減緩眩光的程度？①減少燈具的數量 ②調整…",{"number":31,"session":7,"stem":32},13,"根據 2019 年版綠建築評估手冊之照明節能評估指標，下列何者並非評估項目？",{"number":34,"session":7,"stem":35},14,"有關結露的敘述，下列何者錯誤？",{"number":37,"session":7,"stem":38},16,"依據我國室內空氣品質標準，下列敘述何者錯誤？",{"number":40,"session":7,"stem":41},17,"關於 Predicted Mean Vote（PMV）的敘述，何者錯誤？",{"number":43,"session":7,"stem":44},18,"關於 600 W 攜帶式石英燈管電暖器的熱效應現象，下列敘述何者正確？",[46,49,52,55,58],{"number":10,"session":47,"stem":48},"114180","有關建築牆構造之隔音性能，下列敘述何者錯誤？",{"number":10,"session":50,"stem":51},"113190","某牆壁面積為 15 m2，其中包含一樘玻璃窗，面積 2.4 m2，500 Hz 吸音…",{"number":10,"session":53,"stem":54},"111180","有關多孔質吸音材料的吸音特性敘述，下列何者錯誤？",{"number":10,"session":56,"stem":57},"110180","某鋼筋混凝土屋頂構造，計算屋頂平均熱傳透率 Uar 時，不包括下列那個項目？",{"number":10,"session":59,"stem":60},"109180","有關餘響（reverberation）的敘述，下列何者錯誤？",1791863200999]