[{"data":1,"prerenderedAt":61},["ShallowReactive",2],{"q-113190-arch_construction-28":3},{"question":4,"neighbors":26,"sameNumber":45,"prev":34,"next":37},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":20,"answerS":11,"answerNote":11,"images":21,"explanation":22,"withheld":11,"deepChars":23,"freq":24,"indexable":25},"arch-113190-801-0103-028","architect","113190",113,"建築構造與施工",28,null,"鋼構造採用填角銲進行搭接時，若較薄之板厚度為 d（d＞6 mm），則搭接接頭之最小搭接長度至少須大於下列何者？",{"A":14,"B":15,"C":16,"D":17},"3d","5d","8d","10 d",[19],"B","single",[],"本題考點：鋼構造以填角銲接合兩片疊合鋼板（搭接接頭）時的最小搭接長度構造要求，基準量是「較薄板」的厚度 d，倍數是 5，也就是至少 5d。\n【正解理由】搭接接頭是把兩片鋼板上下疊合，再沿板邊施作填角銲傳力。兩片板的中心線並不在同一直線上，受拉時力的作用線有偏心，接頭會產生附加彎矩，使疊合段傾向轉動、張開，銲道根部因此承受額外的撕裂作用。搭接長度愈短，抵抗這個轉動的力臂愈小，接頭愈容易翹開；所以鋼構造設計對搭接接頭的構造要求，是以較薄板厚度為基準，最小搭接長度取較薄板厚的 5 倍，即 5d。這裡要拆開看三個要件：一是接頭形式必須是「搭接」（疊合），不是對接或 T 形接頭；二是基準量取「較薄」那一片板的厚度，因為較薄板的剛度較低、最先發生轉動與局部彎曲；三是倍數為 5，題目問「至少須大於」的就是這個下限倍數。題幹給定 d＞6 mm，只是交代板厚落在一般鋼板的範圍，判斷倍數時仍以 5d 為準。故選 B。\n【逐項排除】\n(A) 3d：倍數過小。搭接長度只有 3 倍板厚時，疊合段太短，偏心造成的附加彎矩無法靠足夠的疊合長度抵抗，接頭容易轉動張開。最小搭接長度的倍數應為 5，即 5d，3d 低於下限，不符合題目所問。\n(B) 5d：正確。以較薄板厚 d 為基準，最小搭接長度取 5 倍板厚，恰好對應搭接接頭為抑制偏心轉動所需的最小疊合長度，符合題目所問。\n(C) 8d：8d 雖然比 5d 長，搭接得更長在受力上並無不利，但題目問的是「最小搭接長度至少須大於」的下限值，下限是 5d 而非 8d；把 8d 當成最小值會誤把下限抬高，不符合題目所問。\n(D) 10 d：與 (C) 同理，10d 是比下限更長的長度，不是最小搭接長度。下限應為 5d，因此 10d 不符合題目所問。\n【記憶點】填角銲搭接：看「較薄板」厚度 d，最小搭接長度 5d，搭得太短接頭會因偏心而轉動張開。",706,1,true,[27,30,33,36,39,42],{"number":28,"session":7,"stem":29},25,"下列何者為臺灣常見之日式木造建築所使用之木構造結構系統？",{"number":31,"session":7,"stem":32},26,"木構造建築中，關於柱樑系統（或樑柱構架、軸組式）的房屋，下列敘述何者錯誤？",{"number":34,"session":7,"stem":35},27,"下列工法為臺灣常見的木構造工法，對於此工法的敘述何者錯誤？頂部連接件上框窗楣豎框下框…",{"number":37,"session":7,"stem":38},29,"下列鋼結構體工法之描述何項錯誤？",{"number":40,"session":7,"stem":41},30,"有關屋頂合成輕質混凝土板隔熱材之施工方式，下列敘述何者錯誤？",{"number":43,"session":7,"stem":44},31,"有關鋼板的屋頂構造，何項敘述錯誤？",[46,49,52,55,58],{"number":10,"session":47,"stem":48},"114180","下列關於鋼骨鋼筋混凝土（SRC）構造的敘述，何者錯誤？",{"number":10,"session":50,"stem":51},"112190","以下何種面材最不適合應用於「建築基地保水設計技術規範」規定之「透水鋪面」？（基層及接…",{"number":10,"session":53,"stem":54},"111180","下列何者非木料接合固定時常用之鐵件？",{"number":10,"session":56,"stem":57},"110180","下列四種運動場地標準作法的大樣圖，何者錯誤？砂質壤土植草黏土層粉土攙細砂表層碎石透水…",{"number":10,"session":59,"stem":60},"109180","有關剪力牆構造之敘述，下列何者正確？",1791863198416]