[{"data":1,"prerenderedAt":61},["ShallowReactive",2],{"q-113190-arch_construction-41":3},{"question":4,"neighbors":26,"sameNumber":45,"prev":34,"next":37},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":20,"answerS":11,"answerNote":11,"images":21,"explanation":22,"withheld":11,"deepChars":23,"freq":24,"indexable":25},"arch-113190-801-0103-041","architect","113190",113,"建築構造與施工",41,null,"一般鋼構造房屋工地現場的施工順序，何者正確？①樑構件吊裝 ②銲接鎖固 ③基礎螺栓埋設 ④柱構件吊裝 ⑤高拉力螺栓鎖固",{"A":14,"B":15,"C":16,"D":17},"④①②⑤③","③④①⑤②","③⑤④①②","④①③⑤②",[19],"B","single",[],"本題考點：鋼構造房屋工地現場安裝的施工順序，以及高強度螺栓與銲接併用時「先鎖螺栓、後銲接」的先後關係。\n【正解理由】鋼構造的現場作業依「先有支承、再立構件、先暫時固定、後永久接合」的邏輯進行：③基礎螺栓（錨定螺栓）必須在基礎施工階段預先埋設並定位，柱腳底板才有可固定之處；接著④吊裝柱構件，將柱腳套入基礎螺栓並調整位置；柱立起後才能①吊裝樑構件，架設於柱的接頭上，以安裝用螺栓暫時固定形成構架；構架經校正垂直度後，再進行⑤高拉力螺栓鎖固；最後進行②銲接。高強度螺栓與銲接併用時，《建築技術規則建築構造編》第 296 條第 2 項 明定以摩阻型接合設計之高強度螺栓與銲接共同分擔載重時，應先鎖緊高強度螺栓後再銲接；若先銲接，銲道冷卻收縮會使接合板件翹曲、無法密貼，螺栓再鎖也發揮不了設計的摩擦力。因此正確順序為③④①⑤②，故選 B。\n【逐項排除】\n(A) ④①②⑤③ 錯誤，不符之處有兩點：其一，基礎螺栓埋設排在最後，柱吊裝時柱腳沒有可錨定的螺栓，柱無法定位與穩定；其二，銲接排在高拉力螺栓鎖固之前，與 《建築技術規則建築構造編》第 296 條第 2 項 先鎖緊高強度螺栓後再銲接的順序相反。正確的排法是基礎螺栓放在最前面，螺栓鎖固放在銲接之前。\n(B) ③④①⑤② 正確。先埋設基礎螺栓，再依序吊裝柱、樑，構架校正後鎖固高拉力螺栓，最後銲接，符合構件安裝的先後邏輯，也符合 《建築技術規則建築構造編》第 296 條第 2 項 先鎖螺栓後銲接的要求。\n(C) ③⑤④①② 錯誤：雖然基礎螺栓排在最前、銲接排在最後，但高拉力螺栓鎖固排在柱、樑吊裝之前，此時構件尚未就位，沒有可以鎖固的接頭。高拉力螺栓是構件吊裝、校正完成之後才進行的接合作業，正確位置在④①之後、②之前。\n(D) ④①③⑤② 錯誤：基礎螺栓埋設排在柱、樑吊裝之後，柱吊裝時柱腳無處錨定，構架無法穩定架立。雖然⑤在②之前的部分正確，但基礎螺栓須在基礎施工階段先行埋設、排在整個序列的最前面，因此整個順序仍不成立。\n【記憶點】鋼構現場順序「埋基礎螺栓 → 立柱 → 架樑 → 鎖高拉力螺栓 → 銲接」，螺栓先鎖、銲接在後。",778,1,true,[27,30,33,36,39,42],{"number":28,"session":7,"stem":29},38,"關於鋼骨鋼筋混凝土（SRC）的柱、樑構件及其主筋，下列敘述何者正確？",{"number":31,"session":7,"stem":32},39,"混凝土坍度過低不適於澆置時，下列何者錯誤？",{"number":34,"session":7,"stem":35},40,"發生於 2024 年 4 月 3 號的地震，震後可見不少鋼筋混凝土（RC）柱屈曲破壞…",{"number":37,"session":7,"stem":38},42,"建築物外牆貼磁磚，如果只使用黏著劑，經過 20 年後經常掉落，下列那一項方法最不適合…",{"number":40,"session":7,"stem":41},43,"發現直立之女兒牆體有斜紋龜裂滲水，此一場地條件最不適宜選用下列防水材料作處理？",{"number":43,"session":7,"stem":44},44,"張貼石材若以水泥砂漿為黏著材料，日後經雨水浸淋易產生游離石灰水滲出施工勾縫，乾燥後形…",[46,49,52,55,58],{"number":10,"session":47,"stem":48},"114180","有關玻璃外牆（glass facade）之圖示之相關敘述，何者錯誤？結構膠支承構件層…",{"number":10,"session":50,"stem":51},"112190","有關室內裝修工程的敘述，下列何者錯誤？",{"number":10,"session":53,"stem":54},"111180","有關隔震工法之敘述，下列何者錯誤？",{"number":10,"session":56,"stem":57},"110180","下列何者不是 CNS3299-12「陶瓷面磚試驗法-第 12 部：防滑性試驗法」進行…",{"number":10,"session":59,"stem":60},"109180","何種結構補強工法可改善柱的強度而提升耐震能力，但可能導致短梁效應的發生，故不適用於柱…",1791863198537]