[{"data":1,"prerenderedAt":63},["ShallowReactive",2],{"q-114180-arch_construction-46":3},{"question":4,"neighbors":28,"sameNumber":47,"prev":36,"next":39},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":21,"answerS":20,"answerNote":22,"images":23,"explanation":24,"withheld":11,"deepChars":25,"freq":26,"indexable":27},"arch-114180-801-0103-046","architect","114180",114,"建築構造與施工",46,null,"基礎工法中，有關預力混凝土樁（P.C 樁）與一般離心式鋼筋混凝土樁（R.C 樁）之比較，下列敘述何者錯誤？",{"A":14,"B":15,"C":16,"D":17},"P.C 樁除具有 R.C 樁之優點外，且無環列發生之現象","P.C 樁的抗彎矩強度大於同規格之 R.C 樁","P.C 樁的抗衝擊力大於同規格之 R.C 樁","R.C 樁的接頭採用焊接，較 P.C 樁施工容易",[19,20],"A","D","multi","第46題答Ａ或Ｄ或AD者均給分",[],"本題考點：預力混凝土樁（P.C 樁）與離心式鋼筋混凝土樁（R.C 樁）在抗彎、抗打擊、裂損與接樁施工上的差異。\n【正解理由】考選部公告本題答 A 或 D 或 AD 者均給分。P.C 樁是在樁身施加有效預力，使混凝土預先受壓，打樁或受彎時產生的張應力必須先抵銷這份預壓，混凝土才會受拉，所以抗彎與抗衝擊表現都優於同規格的 R.C 樁。《建築物基礎構造設計規範》第 5.6.2 節要求打入式基樁設計時分析打樁的最大壓應力與最大張應力，以避免樁頭或樁身破裂，其中最大張應力的容許值隨有效預力增加而提高。選項 A 說 P.C 樁「無」環列（環向裂損）現象，選項 D 說 R.C 樁焊接接頭「較 P.C 樁施工容易」，依各自所述內容均屬錯誤敘述。故選 A 或 D。\n【逐項排除】\n(A) 錯誤（公告給分選項）。預壓可提高 P.C 樁抵抗開裂的能力，但打入式基樁仍須檢核打樁最大張應力，以避免樁頭或樁身破裂（《建築物基礎構造設計規範》第 5.6.2 節），可見 P.C 樁並非不會發生裂損；改成「P.C 樁因預壓作用，較 R.C 樁不易產生環向裂縫」才正確，關鍵是「較不易」而不是「無」。\n(B) 正確。有效預力使斷面在受彎時須先抵銷預壓才開裂，開裂彎矩與抗彎能力因此提高，同規格下 P.C 樁抗彎矩強度大於 R.C 樁。\n(C) 正確。打樁衝擊在樁身產生反覆的壓應力與張應力波，混凝土最怕受拉；《建築物基礎構造設計規範》第 5.6.2 節的打樁最大張應力容許值包含有效預力，有效預力越大，能承受的打擊張應力越大，所以 P.C 樁抗衝擊力大於同規格 R.C 樁。\n(D) 錯誤（公告給分選項）。離心式 R.C 樁與 P.C 樁都是工廠預鑄的樁節，現場接樁同樣以樁端鋼板對接焊接為主，接頭做法並無 R.C 樁比較容易的差別；改成「兩者接樁均以焊接為主，施工難易相當」才正確。\n【記憶點】預力＝預先壓緊，抗彎、抗打擊較強、較不易裂，但「較不易」不等於「不會」。",829,1,true,[29,32,35,38,41,44],{"number":30,"session":7,"stem":31},43,"構造物於大地定位時，所放樣的軸線交點樁，於土方整地、開挖基礎或地下室時，導致這些樁體…",{"number":33,"session":7,"stem":34},44,"有關清水混凝土（architecture exposed concrete）之敘述，…",{"number":36,"session":7,"stem":37},45,"進行牆體工程以紅磚砌築，其垂直度之控制方式，下列何者錯誤？",{"number":39,"session":7,"stem":40},47,"關於鋼構造建築現場施工的品管和作業要求，下列敘述何者正確？",{"number":42,"session":7,"stem":43},48,"檢查銲道內部缺陷時，常用何種非破壞檢測方式？",{"number":45,"session":7,"stem":46},49,"下列各種屋頂的設備基礎防水收頭細部中，何者可能具有最佳的防水效果？",[48,51,54,57,60],{"number":10,"session":49,"stem":50},"113190","鋼構造之高強度螺栓施工安裝，下列何項描述錯誤？",{"number":10,"session":52,"stem":53},"112190","依營造安全衛生設施標準規定，對於施工構臺應辦理項目，下列敘述何者錯誤？",{"number":10,"session":55,"stem":56},"111180","依據 CNS12642 公共兒童遊戲場設備適用範圍之規定，其使用者年齡範圍為：",{"number":10,"session":58,"stem":59},"110180","下列何者不是「高性能節能玻璃綠建材」規範範圍？",{"number":10,"session":61,"stem":62},"109180","水電配管穿越結構伸縮縫時，下圖那些正確？不鏽鋼配管伸縮縫蓋板吊掛螺桿伸縮接頭部甲吊掛…",1791863196300]