[{"data":1,"prerenderedAt":62},["ShallowReactive",2],{"q-115180-arch_structure-16":3},{"question":4,"neighbors":27,"sameNumber":46,"prev":35,"next":38},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":20,"answerS":11,"answerNote":11,"images":21,"explanation":23,"withheld":11,"deepChars":24,"freq":25,"indexable":26},"arch-115180-801-0102-016","architect","115180",115,"建築結構",16,null,"分析此桁架結構並找出正確桿件內力？ 300 kN 400 kN 60° C B 4m A D 3m",{"A":14,"B":15,"C":16,"D":17},"FAB = 333 kN（壓）","FBC = 150 kN（拉）","FCD = 346 kN（拉）","FBD = 333 kN（拉）",[19],"D","single",[22],"\u002Fimages\u002Farch-115180-801-0102-016.png","本題考點：以節點法求桁架桿件內力，包含斜向外力分解為水平與垂直分量、斜桿方向餘弦的取得，以及由內力正負號判斷拉力或壓力。\n【正解理由】依題圖，B 在 A 的正上方 4 m，C 在 D 的正上方，AD 水平距離 3 m；桿件為 AB、BC、CD 與斜桿 BD，A、D 為鉸支承。B 點受 300 kN 垂直向下，C 點受 400 kN 斜向左下、與水平夾 60°。先處理只有兩根未知桿的 C 點：400 kN 的水平分量 400 × 0.5 = 200 kN（向左），垂直分量 400 × 0.866 = 346.4 kN（向下）。C 點水平方向只有 BC，BC 必須提供向右 200 kN，對 C 點而言是「推」，所以 BC 為 200 kN 壓力；垂直方向只有 CD，必須提供向上 346.4 kN，同樣是推，CD 為 346.4 kN 壓力。接著看 B 點：BD 長度為 √(3² + 4²) = √25 = 5 m，水平方向餘弦 3\u002F5、垂直方向餘弦 4\u002F5。BC 的壓力把 B 點推向左 200 kN，只能由 BD 的水平分量平衡，BD 必須把 B 拉向 D，所以 BD 為拉力，大小 200 ÷ (3\u002F5) = 333.3 kN。最後 B 點垂直方向：300 kN 向下，BD 拉力的垂直分量 333.3 × 4\u002F5 向下，兩者都要由 AB 往上頂，AB 為壓力 300 + 266.7 = 566.7 kN。四個選項中只有 FBD = 333 kN（拉）與計算相符，故選 D。\n【逐項排除】\n(A) FAB = 333 kN（壓）：方向對（AB 確為壓桿），但大小錯。B 點垂直方向要同時承擔 300 kN 外力與 BD 拉力的垂直分量，AB 實際為 566.7 kN 壓力，敘述錯誤。\n(B) FBC = 150 kN（拉）：大小與方向都錯。C 點水平平衡只有 BC 一根桿，必須抵抗 400 kN 的水平分量 200 kN，BC 為 200 kN 的壓力，不是拉力，敘述錯誤。\n(C) FCD = 346 kN（拉）：大小正確（等於 400 kN 的垂直分量 346.4 kN），但方向錯。外力把 C 點往下壓，CD 要往上頂住 C 點，是壓力而非拉力，敘述錯誤。\n(D) FBD = 333 kN（拉）：由 B 點水平平衡，200 ÷ (3\u002F5) = 333.3 kN，且 BD 把 B 拉向 D，為拉力，敘述正確。\n【演算步驟】\n公式：節點力平衡 ΣFx = 0、ΣFy = 0；斜向力分量 Fx = F cos60°、Fy = F sin60°。\n步驟一：400 kN 分量，Fx = 400 kN × 0.5 = 200 kN（向左），Fy = 400 kN × 0.866 = 346.4 kN（向下）。\n步驟二：C 點 ΣFx = 0 → FBC = 200 kN（壓）；ΣFy = 0 → FCD = 346.4 kN（壓）。\n步驟三：BD 長度 = √(3² + 4²) m = √25 m = 5 m，cos = 3\u002F5、sin = 4\u002F5。\n步驟四：B 點 ΣFx = 0 → FBD × 3\u002F5 = 200 kN → FBD = 200 kN × 5 \u002F 3 = 333.3 kN（拉）。\n步驟五：B 點 ΣFy = 0 → FAB = 300 kN + 333.3 kN × 4\u002F5 = 300 kN + 266.7 kN = 566.7 kN（壓）。\n【記憶點】節點法從「只剩兩根未知桿」的節點下手；內力方向看「桿件對節點是拉還是推」，大小對了方向錯一樣是錯。",464,1,true,[28,31,34,37,40,43],{"number":29,"session":7,"stem":30},13,"如圖所示桁架受外力作用，共有幾支零桿（Zero-force member）？",{"number":32,"session":7,"stem":33},14,"下圖為一受力之對稱簡支桁架，其零桿為何？",{"number":35,"session":7,"stem":36},15,"承上題，試問其受拉、受壓最大桿件為何？其軸力分別是多少？",{"number":38,"session":7,"stem":39},17,"圖示受荷重的桁架結構的構件內力與方向的敘述，下列何者錯誤？ B C D 4m I J…",{"number":41,"session":7,"stem":42},18,"桁架結構如下圖，桿件 CE 的軸向力為何？ P P D E F 3m A B C 3…",{"number":44,"session":7,"stem":45},19,"某懸索系統由三段纜繩組成（見下圖），其中 AB 段與 BC 段間、及 BC 段與 C…",[47,50,53,56,59],{"number":10,"session":48,"stem":49},"114180","圖中所示一正三角形桁架，求可施加之最大負載 P，使得無任何桿件受力超過 3 kN 之…",{"number":10,"session":51,"stem":52},"113190","一剛架結構受外力作用如圖所示，下列何種梁上塑性鉸產生時，不會形成不穩定結構？",{"number":10,"session":54,"stem":55},"112190","下列何種設計策略會增長建物基本振動週期？",{"number":10,"session":57,"stem":58},"111180","關於柱子的挫屈（buckling）破壞與臨界負載（critical load）之敘述…",{"number":10,"session":60,"stem":61},"110180","建築物耐震設計規範的鋼骨造結構系統中，常採用偏心斜撐結構系統。此系統的主要消能機制一…",1795751976728]