[{"data":1,"prerenderedAt":62},["ShallowReactive",2],{"q-115180-arch_structure-30":3},{"question":4,"neighbors":27,"sameNumber":46,"prev":35,"next":38},{"id":5,"classKey":6,"session":7,"year":8,"subject":9,"number":10,"groupStem":11,"ownStem":12,"stem":12,"options":13,"answer":18,"answerKind":20,"answerS":11,"answerNote":11,"images":21,"explanation":23,"withheld":11,"deepChars":24,"freq":25,"indexable":26},"arch-115180-801-0102-030","architect","115180",115,"建築結構",30,null,"已知鋼筋混凝土梁斷面的寬及有效深度分別為 30 及 45 cm，混凝土之 f c′ 為 210 kgf\u002Fcm2，鋼 A 筋之 f y 為 2800 kgf\u002Fcm2。若垂直剪力肋筋採#3 鋼筋，間距 20 cm（ v = 0.071 ），則該梁斷面 s 之剪力計算強度 Vn 為何？ Vn = Vc + Vs = 0.53 fc′bd + f y · Av · d s",{"A":14,"B":15,"C":16,"D":17},"19.3 kgf","193 kgf","1.93 tf","19.3 tf",[19],"D","single",[22],"\u002Fimages\u002Farch-115180-801-0102-030.png","本題考點：鋼筋混凝土梁的標稱剪力強度 Vn = Vc + Vs，混凝土貢獻 Vc = 0.53√fc′ b d 與剪力鋼筋貢獻 Vs = fy (Av\u002Fs) d 的代入計算，以及 kgf 與 tf 的單位換算。\n【正解理由】題目已給公式 Vn = Vc + Vs = 0.53√fc′ b d + fy · Av · d \u002F s，並給 b = 30 cm、d = 45 cm、fc′ = 210 kgf\u002Fcm²、fy = 2800 kgf\u002Fcm²、Av\u002Fs = 0.071（cm²\u002Fcm）。混凝土部分：√210 = 14.491（kgf\u002Fcm² 的開根號），Vc = 0.53 × 14.491 × 30 × 45 = 10368.3 kgf。鋼筋部分：Vs = 2800 × 0.071 × 45 = 8946 kgf。兩者相加 Vn = 10368.3 + 8946 = 19314.3 kgf，換算為 tf 為 19314.3 ÷ 1000 = 19.31 tf，約 19.3 tf，故選 D。\n【逐項排除】\n(A) 19.3 kgf：數字與正確答案相同，但單位錯成 kgf，比正確值小了好幾個數量級，等於把整根梁的剪力強度算成一顆小砝碼的重量，不符合題目所求。\n(B) 193 kgf：同樣以 kgf 為單位，數量級遠小於實際的 19314.3 kgf，不符合題目所求。\n(C) 1.93 tf：以 tf 為單位，但數值明顯偏小，與 19.31 tf 不符，不符合題目所求。\n(D) 19.3 tf：Vc 與 Vs 相加得 19314.3 kgf，換算為 19.31 tf，符合題目所求。\n【演算步驟】\n公式：Vn = Vc + Vs = 0.53√fc′ b d + fy (Av\u002Fs) d\n步驟一：√fc′ = √(210 kgf\u002Fcm²) = 14.491（kgf\u002Fcm² 的開根號單位，本公式之慣用單位系統）。\n步驟二：b × d = 30 cm × 45 cm = 1350 cm²。\n步驟三：Vc = 0.53 × 14.491 × 1350 cm² = 10368.3 kgf。\n步驟四：Vs = 2800 kgf\u002Fcm² × 0.071 cm²\u002Fcm × 45 cm = 8946 kgf。\n步驟五：Vn = 10368.3 kgf + 8946 kgf = 19314.3 kgf。\n步驟六：Vn = 19314.3 kgf ÷ 1000 kgf\u002Ftf = 19.31 tf ≒ 19.3 tf。\n【記憶點】剪力強度＝混凝土「0.53√fc′ b d」＋箍筋「fy (Av\u002Fs) d」；代完數字一定要回頭檢查單位，選項常只差單位。",576,1,true,[28,31,34,37,40,43],{"number":29,"session":7,"stem":30},27,"根據「建築物混凝土結構設計規範」，為確保鋼筋混凝土結構之耐震性，下列設計原則何者正確…",{"number":32,"session":7,"stem":33},28,"鋼筋混凝土結構中，拉力鋼筋欲發揮其優良變形能力，須確保足夠之端部錨定長度。在拉力鋼筋…",{"number":35,"session":7,"stem":36},29,"關於鋼筋混凝土梁的敘述，下列何者正確？",{"number":38,"session":7,"stem":39},31,"下列何者可有效確保鋼筋混凝土梁構件之韌性？",{"number":41,"session":7,"stem":42},32,"下列鋼結構設計策略中，何者無法有效降低柱發生挫屈（buckling）破壞的可能性？",{"number":44,"session":7,"stem":45},33,"有關建築結構設計之觀念，下列敘述何者較不適當？",[47,50,53,56,59],{"number":10,"session":48,"stem":49},"114180","關於鋼筋混凝土柱，下列敘述何者正確？",{"number":10,"session":51,"stem":52},"113190","關於鋼筋混凝土梁桿件之「平衡鋼筋比」，下列敘述何者錯誤？",{"number":10,"session":54,"stem":55},"112190","以下鋼結構斜撐系統中，何者側向勁度最高？",{"number":10,"session":57,"stem":58},"111180","四組鋼造構架經耐震設計如下圖所示，其門型框架與斜撐斷面均同，僅斜撐配置不同，其中桿件…",{"number":10,"session":60,"stem":61},"110180","無梁版系統在我國較少應用於上部結構，大多僅應用在地下室結構，下列敘述何者錯誤？",1795751976859]